Campbell Scientific LoggerNet Datalogger Support Software User Manual
Page 537

Appendix E. Log Files
TABLE E-1. Transaction Log Messages
Code
Message Text
Message Parameters
Message Meaning
User Response to
Message
15
Starting BMP
data advise
transaction
A start data advise
operation has been
initiated. Data advise
is not in place until
the datalogger
responds.
16
Stopping BMP
data advise
transaction
A stop data advise
operation has been
initiated.
17
BMP data
advise
transaction
started
The message from
the datalogger
confirming the start
of data advise has
been received.
18
BMP data
advise
transaction
stopped
The message from
the datalogger
confirming the
suspension of data
advise has been
received.
19
BMP data
advise
transaction
failed
The attempt to start
or stop a data advise
with the datalogger
has failed or the
operation has timed
out waiting for a
response.
Check communications
with the datalogger by
trying to check the
clock. If that fails
follow the steps for
message 14.
20
Hole detected
Table name; Beginning
record number; Ending
record number
A hole or missed
records has been
detected in the data
coming from the
datalogger.
The server will
automatically try to
collect the data if hole
collection is enabled.
21
Hole collected
Table name; Beginning
record number; Ending
record number
The missing records
specified have been
collected from the
datalogger.
22
Hole lost
Table name; Beginning
record number; Ending
record number
The missing records
have been
overwritten in the
datalogger.
23
Hole collect
start
Table name; Beginning
record number; Ending
record number
The hole collect
request has been
started. This
message won’t go to
the datalogger until
the BMP1 message is
sent. (see message
104)
E-5