Section 14. Troubleshooting Guide

This section is provided as an aid to solving some of the common problems that might be

encountered using the LoggerNet software. This list is not comprehensive but should

provide some insight and ability to correct simple errors without a call to Campbell

Scientific technical support.

This section also includes descriptions of some of the tools such as Terminal Emulator and

Data Table Monitor that can be useful in troubleshooting LoggerNet problems.

14.1 What’s Changed?

When things stop working the most important thing to ask yourself is: “What’s

changed?” A new computer, new software (especially non-Campbell Scientific

software), different communication peripheral such as a new modem, new

datalogger program, etc., can all interrupt communications. If you can’t

deduce the nature of the problem, go back to the original configuration. If a

phone telecommunications or socket link starts to fail for no apparent reason,

ask someone else to try it from a different computer. Try swapping out

components – one at a time – from a link in the network that you know works

or from spare equipment that you are certain is functioning correctly.

Sometimes the smallest thing – a cable or a new PC utility program – can cause

widespread havoc. If using TCP/IP or cellular telephone communications,

check with the network administrator to see if anything changed that coincided

with the loss of communications.

14.2 LoggerNet Server Problems

The following sections identify problems that have been observed with

operation of the server. If you are experiencing problems with the server look

through the following conditions to see if any of these match the problem you

are having. If you find the problem listed, try the suggested remedies. If your

problem is not listed or the remedies don’t fix the problem, contact Campbell

Scientific for technical assistance.

14.2.1 Starting LoggerNet and Connecting to the Server

Problem: Cannot start LoggerNet on a laptop computer. (Error message

“LoggerNet was unable to start the communications server.” Socket Failure

creation 10047.”)

Remedy 1: If the computer is sometimes used on a computer

network and no network card is installed, TCP-IP services may not be

starting. Try starting the computer with the network adapter card

installed.

Remedy 2: If remedy 1 doesn’t work, you will need to configure a

non-existent dial-up service with a fixed IP address. There is a

description of this procedure in Section 1.2, Configuration of TCP/IP

Service.