8 editing comments, instructions, and expressions, 9 cut, copy, paste, and clipboard options, 3 library files – Campbell Scientific LoggerNet Datalogger Support Software User Manual
Page 283: 4 documenting a dld file, Cut, copy, paste, and clipboard options -65, Library files -65, Documenting a dld file -65

Section 7. Creating and Editing Datalogger Programs
7.4.2.8 Editing Comments, Instructions, and Expressions
To edit Comments, Expressions, and Instruction parameters, move the cursor
to the appropriate text and retype it. To delete an instruction when the cursor is
somewhere within the instruction, select Edit | Delete Instruction or press
. An instruction or block of instructions can also be selected and
deleted with the delete key. The entire instruction must be selected or an error
message will be returned.
7.4.2.9 Cut, Copy, Paste, and Clipboard Options
Edit | Delete , Edit | Cut, Edit | Copy, and Edit | Paste allow sections of the
program to be deleted, moved, or copied to another area of the program or
between programs. Edit | Show Clipboard shows the contents of the clipboard.
You cannot move, copy, delete or comment out protected text
(Tables, Execution Intervals) or partial instructions. To move,
copy or delete an Instruction, the entire instruction, including all
of the parameters, must be selected.
Cutting and pasting between datalogger programs should only be between
programs for the same datalogger type. Instructions and parameters may differ
between dataloggers. The compiler will catch many of these errors; however,
this may be at the expense of much time and confusion.
7.4.3 Library Files
Library files can be created to store portions of programs, which can then be
inserted into a different program. Library files are useful if you want to write
different programs for the same sensor set, or it you have several stations that
have similar, but not identical, sensor sets.
To create a library file, select the text to be stored and then select Edit | Save
To Library File. When the window appears, type in the library file name. To
insert a library file in a program, move the cursor to the desired insertion point
and select Edit | Insert Library File.
Library files created for one type of datalogger type should not be
used in programs for a different datalogger type; i.e., a library file
for a CR10X-TD should not be used in a program for a CR10X or
a CR510-TD. Instructions differ among dataloggers, and bringing
in an invalid instruction to a datalogger could result in errors.
7.4.4 Documenting a DLD File
The CSI file is the file created by Edlog that is used to generate the DLD code
and other files. If for some reason your CSI file is missing, you can import the
DLD file into Edlog to create another editable CSI file. From the Edlog menu
select File | Document DLD. Select the DLD file to be imported and remember
to save the file to create a new CSI file.
NOTE
NOTE
7-65