HP XP Continuous Access Software User Manual
Page 89

Using RAID Manager
89
d
If no $HORCMPERM file exists, then the following commands can be
manually executed to permit the use of all volumes the host is currently
allowed to see (LUN security products may or may not be in place).
HP-UX
'ioscan –fun | grep rdsk | /HORCM/usr/bin/raidscan –find inst'
Linux
'ls /dev/sd* | /HORCM/usr/bin/raidscan –find inst'
Solaris
'ls /dev/rdsk/* | /HORCM/usr/bin/raidscan –find inst'
AIX
'lsdev –C –c disk | grep hdisk | /HORCM/usr/bin/raidscan –find
inst'
If the lsdev command does not show the TID and LUN (for example,
2F-00-00-2,0) in the column output for the devices as shown below, then
the –d[g] raw device option (on all commands) and raidscan –find will be
unable to find target devices.
# lsdev
–
C
–
c disk
hdisk1 Defined 04-02-01 Other FC SCSI Disk Drive
This happens when a Fibre Channel adapter is used with a different device
driver (for example, an Emulex adapter with an AIX driver).
MPE/iX
'callci dstat | /HORCM/usr/bin/raidscan -find inst'
Windows NT/2000/2003
'echo hd0-999 | x:\HORCM\etc\raidscan.exe -find inst'
The MAX volume to be scanned is 1000 by default.