128

HP StorageWorks Disk Array XP RAID Manager: User’s Guide

DEVICE_FILE PORT SERIAL LDEV
CTG H/M/12 SSID R:Group PRODUCT_ID
Volume{cec25efe-d3b8-11d4-aead-00c00d003b1e}\Vol3\Dsk0 CL2-D 62496 256
- - - - OPEN-3-CVS-CM

An example using the –fp option:

# ls /dev/rdsk/c57t4* | ./inqraid -CLI -fp
DEVICE_FILE PORT SERIAL LDEV CTG C/B/12 SSID R:Group PRODUCT_ID
c57t4d0* CL1-D 62496 32 - s/P/ss 0004 5:01-03 OPEN-3
c57t4d3* CL1-D 62496 35 - s/P/ss 0004 5:01-03 OPEN-3
c57t4d4 CL1-D 62496 36 - s/P/ss 0004 5:01-01 OPEN-3
c57t4d5 CL1-D 62496 37 - s/P/ss 0004 5:01-02 OPEN-3

The following examples display the relationship between a special file and
the actual physical drive in the disk array, by using the inqraid and system
commands.

HP-UX

# ioscan -fun | grep rdsk | ./inqraid

/dev/rdsk/c0t2d0 ->[HP] CL2-D Ser = 30053 LDEV = 8 [HP ] [OPEN-3 ]

CA = SMPL BC[MU#0 = SMPL MU#1 = SMPL MU#2 = SMPL]

/dev/rdsk/c0t2d1 ->[HP] CL2-D Ser = 30053 LDEV = 9 [HP ] [OPEN-3]

CA = SMPL BC[MU#0 = SMPL MU#1 = SMPL MU#2 = SMPL]

/dev/rdsk/c0t4d0 ->[HP] CL2-D Ser = 30053 LDEV = 14 [HP] [OPEN-3 CM]

Linux

# ls /dev/sd* | ./inqraid
/dev/sdg ->CHNO = 0 TID = 1 LUN = 6
[HP] CL2-B Ser = 30053 LDEV = 22 [HP ] [OPEN-3 ]
CA = SMPL BC[MU#0 = SMPL MU#1 = SMPL MU#2 = SMPL]
/dev/sdh ->CHNO = 0 TID = 1 LUN = 7
[HP] CL2-B Ser = 30053 LDEV = 23 [HP ] [OPEN-3 ]
CA = SMPL BC[MU#0 = SMPL MU#1 = SMPL MU#2 = SMPL]
/dev/sdu -> CHNO = 0 TID = 1 LUN = 14
[HP] CL2-G Ser = 63528 LDEV =2755 [HP ] [OPEN-0V ]
CA = SMPL BC[MU#0 = SMPL MU#1 = SMPL MU#2 = SMPL]
SNAPS[PoolID 0001] SSID = 0x000B
/dev/sdv -> CHNO = 0 TID = 1 LUN = 15
[HP] CL2-G Ser = 63528 LDEV =2768 [HP ] [OPEN-0V ]
CA = SMPL BC[MU#0 = SMPL MU#1 = SMPL MU#2 = SMPL]
UNMAP[Group 00000] SSID = 0x000B
/dev/sdw -> CHNO = 0 TID = 1 LUN = 16
[HP] CL2-G Ser = 63528 LDEV =2769 [HP ] [OPEN-V ]
CA = SMPL BC[MU#0 = SMPL MU#1 = SMPL MU#2 = SMPL]
E-LUN[Group 16384] SSID = 0x000B