HP StorageWorks Disk Array XP RAID Manager: User’s Guide
mirror_unit is omitted, the value of h0 will be assumed.
Mirror unit value “h1”, “h2” and “h3” are valid only for
CA-Journal operations.
Example
HORCM_MON
#ip_address
service
poll(10ms
timeout(10ms)
HST1
horcm
1000
3000
HORCM_CMD
#dev_name dev_name dev_name
/dev/rsd0e
HORCM_DEV
#dev_group
dev_name
port#
TargetID
LU#
MU#
Group
dev
CL1-A
3
1
Group1
dev1
CL1-A
3
1
0
Group2
dev2
CL1-A
3
1
1
Group3
dev3
CL1-A
3
1
2
Group4
dev4
CL1-A
3
1
h1
HORCM_INST
#dev_group
ip_address
service
Group
HST2
horcm
Group1
HST3
horcm
The validity of the mirror descriptor is shown for
various pair states in the tables below.
MU# in CA and CA Journal
MU# in BC and SnapShot
Feature
SMPL
P-VOL
S-VOL
MU#0
MU#1-3 MU#0
MU#1-3 MU#0 MU#1-3
CA
Valid
Invalid
Valid
Invalid
Valid
Invalid
CA-Journal Valid
Valid
Valid
Valid
Valid
Valid
Feature
SMPL
P-VOL
S-VOL
MU#0-2 MU#3-63 MU#0-2 MU#3-63 MU#0 MU#1-63
BC
Valid
Invalid
Valid
Invalid
Valid
Invalid
SnapShot Valid
Valid
Valid
Valid
Valid
Invalid