HP XP Continuous Access Software User Manual
Page 209
209
PairVol
The paired volume name (dev_name) within the group
defined in the configuration definition file.
M
The MU# defined in the configuration definition file.
For CA, the MU# is shown as –. For BC, the MU# is
shown as 0, 1, or 2.
Device_File
The Device_File that is registered to the LDEV map
tables within RM.
UID
The unit ID for multiple array configurations. If UID is
displayed as –, a command device (HORCM-CMD) has
not been found.
S/F
Shows whether a port is SCSI or Fibre Channel.
PORT
The port number.
TARG
The target ID (converted by the fibre conversion table).
LUN
The logical unit number (converted by the fibre
conversion table).
SERIAL
The production (serial) number of the disk array.
LDEV
The LDEV number.
PRODUCT_ID
The product ID field from the STD inquiry page.
Examples
raidscan
using the –CLI option formats the display so that all the columns
are aligned.
# raidscan –p CL1-C –CLI
Port# TargetID# Lun# Seq# Num LDEV# P/S Status Fence P-Seq# P-LDEV#
CL1-C 1 0 30053 1 274 SMPL - - - -
CL1-C 2 2 30053 1 260 P-VOL PAIR NEVER 30053 268
CL1-C 2 3 30053 1 261 P-VOL PAIR NEVER 30053 269
If you specify the –CLI option, raidscan will not
display the cascading mirror (MU1-4).