Command errors, Command errors 273 – HP XP Continuous Access Software User Manual
Page 273
Troubleshooting RAID Manager
273
Command errors
Command Error Problem
Action
EX_ATTDBG
This command failed to communicate
with RM, or a log directory file could
not be created.
Verify that RM is functioning properly.
EX_ATTHOR
Connection could not be made with
RM.
Verify that RM has started and that the
correct HORCMINST value has been
defined.
EX_CMDIOE
The request to the command device
either failed or was rejected.
Check to see whether the syslog file of
the host reports an Illegal Request (0x05)
Sense Key, if so, then verify:
• The BC/CA functions are installed on
the disk array;
• The ESCON RCP and LCP ports are
set properly;
• The CU paths have been established;
• The target volume is available.
EX_CMDRJE
The request to the command device
either failed or was rejected.
Verify the following:
• The BC/CA functions are installed on
the disk array.
• The ESCON RCP and LCP ports are
set properly.
• The CU paths have been established.
• The target volume is available.
EX_COMERR
This command failed to communicate
with RM.
Verify that RM is running.
EX_ENAMLG
Undefined error.
Call the HP support center.
(continued)