beautypg.com

Porting notice for openvms, Introduction, Requirements and restrictions – HP XP Continuous Access Software User Manual

Page 378: Porting notice for openvms 378, Introduction 378 requirements and restrictions 378

background image

378

HP StorageWorks Disk Array XP RAID Manager: User’s Guide

Porting notice for OpenVMS

Introduction

RM uses the UNIX domain socket for IPC (Inter Process Communication).
While OpenVMS does not support the AF_UNIX socket, RAID Manager
uses the Open VMS mailbox driver for inter-process communication
between RAID Manager commands and the HORCM daemon.

Requirements and restrictions

Version of OpenVMS

RM uses CRTL, and needs the following version to support the ROOT
directory for POSIX:

• OpenVMS Version 7.3-1 or later

The CRTL version must be installed before running RM.

SYS$POSIX_ROOT

You need to define the POSIX_ROOT before running RAID Manager

Example:

$ DEFINE/TRANSLATION=(CONCEALED,TERMINAL)
SYS$POSIX_ROOT "Device:[directory]"

Mailbox driver

You need to redefine LNM$TEMPORARY_MAILBOX in the
LNM$PROCESS_DIRECTORY

table as shown below.

Example

$ DEFINE/TABLE=LNM$PROCESS_DIRECTORY
LNM$TEMPORARY_MAILBOX LNM$GROUP

This manual is related to the following products: