HP XP Continuous Access Software User Manual
Page 125
RAID Manager command reference
125
Group PairVol(L/R) (Port#,TID,LU-M),Seq#,LDEV#.P/S,Status, Seq#,P-LDEV# M
horc1 dev00(L) (CL2-J , 0, 0-0)61456 192..S-VOL SSUS,----- 193 -
->/dev/rdsk/c23t0d0
Group PairVol(L/R) (Port#,TID,LU-M),Seq#,LDEV#.P/S,Status, Seq#,P-LDEV# M
horc1 dev10(L) (CL2-J , 2, 3-0)61456 209..S-VOL SSUS,----- 206 -
->/dev/rdsk/c23t2d3
Examples using the –findc option:
HP-UX
# echo /dev/rdsk/c23t0d0 /dev/rdsk/c23t2d3 | ./inqraid -findc
DEVICE_FILE M Group PairVol P/S Stat R_DEVICE M P/S Stat LK
c23t0d0 0 horc1 dev00 S-VOL SSUS c23t0d1 0 P-VOL PSUS OK
/dev/rdsk/c23t0d0[1] -> No such on the group
/dev/rdsk/c23t0d0[2] -> No such on the group
DEVICE_FILE M Group PairVol P/S Stat R_DEVICE M P/S Stat LK
c23t2d3 0 horc1 dev10 S-VOL SSUS c23t2d2 0 P-VOL PSUS OK
/dev/rdsk/c23t2d3[1] -> No such on the group
/dev/rdsk/c23t2d3[2] -> No such on the group
# echo /dev/rdsk/c23t0d0 /dev/rdsk/c23t2d3 | ./inqraid -findc -CLI
DEVICE_FILE M Group PairVol P/S Stat R_DEVICE M P/S Stat LK
c23t0d0 0 horc1 dev00 S-VOL SSUS c23t0d1 0 P-VOL PSUS OK
c23t2d3 0 horc1 dev10 S-VOL SSUS c23t2d2 0 P-VOL PSUS OK
An example using the –CLI option:
Linux
# ls /dev/sd* | ./inqraid -CLI
DEVICE_FILE PORT SERIAL LDEV CTG C/B/12 SSID R:Group PRODUCT_ID
sdh CL2-G 63528 15360 - s/s/ss 0100 5:01-09 OPEN-V
sdu CL2-G 63528 2755 - s/s/ss 000B S:00001 OPEN-0V
sdv CL2-G 63528 2768 - s/s/ss 000B U:00001 OPEN-0V
sdw CL2-G 63528 2769 - s/s/ss 000B E:16384 OPEN-V
An example using the –CLIW option:
# echo /dev/rdsk/c23t0d0 /dev/rdsk/c23t0d1 | ./inqraid -CLIW
DEVICE_FILE WWN AL PORT LUN SERIAL LDEV PRODUCT_ID
c23t0d0 500060e802f01018 C3 CL2-J 0 61456 192 OPEN-3
c23t0d1 500060e802f01018 C3 CL2-J 1 61456 193 OPEN-3
DEVICE_FILE WWN AL PORT LUN SERIAL LDEV PRODUCT_ID
c0t2d3 5000E000E0005000 3E CL1-A 20 30015 2054 OPEN3-CVS
An example using the –sort –CM option:
HP-UX