HP XP Continuous Access Software User Manual
Page 388
388
HP StorageWorks Disk Array XP RAID Manager: User’s Guide
SYS$POSIX_ROOT:[etc]horcm0.conf
HORCM_MON
#ip_address service poll(10ms timeout(10ms)
127.0.0.1 30001 1000 3000
HORCM_CMD
#dev_name dev_name dev_name
DKA145
You will have to start HORCM without a description for HORCM_DEV
and HORCM_INST because target ID and LUN are unknown.
You can determine the mapping of a physical device with a logical name by
using raidscan -find.
Executing a “horcmstart 0”
$ run /DETACHED SYS$SYSTEM:LOGINOUT.EXE
/PROCESS_NAME=horcm0 -
_$ /INPUT=VMS4$DKB100:[SYS0.SYSMGR.][horcm]
loginhorcm0.com
-
_$ /OUTPUT=VMS4$DKB100:[SYS0.SYSMGR.][horcm]run0.out -
_$ /ERROR=VMS4$DKB100:[SYS0.SYSMGR.][horcm]run0.err
%RUN-S-PROC_ID, identification of created process is
00004160
DKA145
CL1-H
30009 145
-
-
-
-
OPEN-9-CM
DKA146
CL1-H
30009 146
-
s/S/ss
0004
5:01-11
OPEN-9
DKA147
CL1-H
30009 147
-
s/P/ss
0004
5:01-11
OPEN-9
DKA148
CL1-H
30009 148
-
s/S/ss
0004
5:01-11
OPEN-9
DKA149
CL1-H
30009 149
-
s/P/ss
0004
5:01-11
OPEN-9
DKA150
CL1-H
30009 150
-
s/S/ss
0004
5:01-11
OPEN-9
DKA151
CL1-H
30009 151
-
s/P/ss
0004
5:01-11
OPEN-9