beautypg.com

HP XP Continuous Access Software User Manual

Page 208

background image

208

HP StorageWorks Disk Array XP RAID Manager: User’s Guide

–z

Makes this command enter interactive mode.

–zx

(Not for use with MPE/iX or OpenVMS)

Prevents using

RM in interactive mode.

–m

MU#

Displays the cascading mirror descriptor. If you specify
the –CLI option, raidscan will not display the
cascading mirror (MU1-4).

-m all

will display all cascading mirror descriptors.

Output Fields

Port#

The port name on the disk array.

ALPA/C

Arbitrated loop physical address of the port on the disk
array.

TargetID#(TID#)

The SCSI/Fibre Channel target ID of specified port.

LUN#(LU#)

The logical unit number of specified target ID in the
disk array.

Num(LDEV#...)

The number of LDEV and LDEV# that used LUSE
volume on the disk array.

P/S

The (P-VOL, S-VOL) attribute of a volume.

Status

The status of the paired volume in the disk array.

P-Seq#

Seq# (production serial number) of the pair partner
array.

P-LDEV#

LDEV# of the partner that becomes a pair in or among
the disk array.

Vol.Type

Type name of volume mapped to LUN.

Group

The group name (dev_group) described in the
configuration definition file.

This manual is related to the following products: