HP StorageWorks Disk Array XP RAID Manager: User’s Guide

Commands from HOSTA, Instance 1 shown on

page 307

The following examples employ RM commands from HOSTA, Instance 1.

• Set the instance number. (If C shell)

# setenv HORCMINST 1

(Windows NT/2000/2003)

set HORCMINST=1

• Set the HORCC_MRCF environment variable. (If C shell)

# setenv HORCC_MRCF 1

(Windows NT/2000/2003)

set HORCC_MRCF=1

• Designate group names (Oradb and Oradb1) and a remote instance

P-VOL:

# paircreate -g Oradb -vr

# paircreate -g Oradb1 -vl

This command begins a pair coupling between the four pairs of
volumes designated as Oradb and Oradb1 in the configuration
definition file.

• Designate a group name and confirm pair states:

# pairdisplay -g oradb –m cas
Group PairVol(L/R) (Port#,TID,LU-M), Seq#, LDEV#..P/S, Status, Seq#, P-LDEV# M
oradb oradev1(L) (CL1-D, 2, 1-0) 30053 268..P-VOL PAIR ----- 266 -
oradb oradev11(R) (CL1-D, 2, 1-1) 30053 268..S-VOL PAIR 30053 270 -
oradb1 oradev21(L) (CL1-D, 2, 1-2) 30053 268..P-VOL ---- ----- ---- -
oradb2 oradev1(R) (CL1-A, 1, 1-0) 30053 266..SMPL PAIR 30053 268 -
oradb oradev2(L) (CL1-D, 2, 2-0) 30053 269..P-VOL PAIR ----- 267 -
oradb1 oradev12(R) (CL1-D, 2, 2-1) 30053 269..S-VOL PAIR 30053 271 -
oradb2 oradev22(L) (CL1-D, 2, 2-2) 30053 269..P-VOL ---- ----- ---- -
oradb oradev2(R) (CL1-A, 1, 2-0) 30053 267..SMPL PAIR 30053 269 -