HP XP Continuous Access Software User Manual
Page 198
![background image](/manuals/398587/198/background.png)
198
HP StorageWorks Disk Array XP RAID Manager: User’s Guide
For the XP12000, the expanded ports CL3-A up to
CL3-R, or CLG-A up to CLG-R can be selected.
Port specification is not case sensitive (CL1-A= cl1-a=
CL1-a= cl1-A).
lun
Specifies a LUN of a specified SCSI/Fibre Channel
target.
targ
Specifies a SCSI/Fibre Channel target ID of a specified
port.
mun
(BC/SnapShot only) Specifies the duplicated mirroring
descriptor (MU#) for the identical LU under
BC/SnapShot in a range of 0 to 2/63.
–pd raw_device
(HP-UX, Linux, Solaris, Windows NT/2000/2003, AIX,
and MPE/iX only)
Allows the designation of an LDEV
via the specified raw_device file.
–q
Terminates interactive mode and exits this command.
–s
[interval] [count] or –sm [interval] [count]
Designates the monitoring time interval.
–s
option interprets the time interval in seconds.
–sm
option interprets the time interval in minutes.
interval
Specify from 1 to 60. The default value is 3.
count
Specifies a number of repetitions. When omitted, the
command repeats until cancelled via CNTL-C.
–z
Makes the command enter interactive mode. The
interactive mode can be used to enter the –p options.
This command begins an activity based on the –s
options. This command returns to non-interactive mode
upon receiving CNTL-C. Interactive mode is
terminated through the –q option or RM shut-down.