HP XP Continuous Access Software User Manual
Page 252
252
HP StorageWorks Disk Array XP RAID Manager: User’s Guide
–v cflag
Displays all flags for checking regarding data block
validation for target volumes.
Example
# raidvchkscan -p CL1-A -v cflag
PORT# /ALPA/C TID# LU# Seq# Num LDEV# BR-W-E-E MR-W-B BR-W-B SR-W-B-S
CL1-A / ef/ 0 0 0 2332 1 0 D E B R D D D D E E D E D D
CL1-A / ef/ 0 0 1 2332 1 1 D E B R D D D D E E D E D D
CL1-A / ef/ 0 0 2 2332 1 2 D E B R D D D D E E D E D D
CL1-A / ef/ 0 0 3 2332 1 3 D E B R D D D D E E D E D D
CL1-A / ef/ 0 0 4 2332 1 4 D E B R D D D D E E D E D D
BR-W-E-E
displays the flags for checking data block
size.
R=Read
→ E=Enable and D=Disable
W=Write
→ E=Enable and D=Disable
E=Endian format
→ L=Little and B=Big
E=Not rejected when validation error
→ W=Write
and R=Read
MR-W-B
displays the flags for checking block header
information.
R=Read
→ E=Enable and D=Disable
W=Write
→ E=Enable and D=Disable
B=Block #0
→ E=Enable and D=Disable
BR-W-B
displays the flags for checking data block
number information.
R=Read
→ E=Enable and D=Disable
W=Write
→ E=Enable and D=Disable
B=Data Block
→ E=Enable and D=Disable
SR-W-B-S
displays the flags for checking data block
checksum.
R=Read
→ E=Enable and D=Disable
W=Write
→ E=Enable and D=Disable
B=Block #0
→ E=Enable and D=Disable
S=Checksum
→ E=Enable and D=Disable