Raidvchkscan, Raidvchkscan 250 – HP XP Continuous Access Software User Manual
Page 250
250
HP StorageWorks Disk Array XP RAID Manager: User’s Guide
raidvchkscan
Integrity checking confirmation command
Data Integrity Check only
Description
The raidvchkscan command sets the parameters for protection checking to
the specified volumes.The unit of checking for the protection is based on
the raidscan command.
Syntax
raidvchkscan
{ –h | –q | –z[x] | –p port [hgrp] | –pd[g] raw_device |
–s
seq# | –t target | –l LUN | –fx | –v operation }
Arguments
–h
Displays Help/Usage and version information.
–q
Terminates interactive mode and exits this command.
–z
This option makes this command enter interactive
mode.
–zx
(Not for use with MPE/iX or OpenVMS)
This option
prevents using RM in interactive mode.
–p port
Specifies the name of a port to be scanned by selecting
it from CL1-A to CL1-R (excluding CL1-I and CL1-O),
or CL2-A to CL2-R (excluding CL2-I and CL2-O). For
the expanded port, specify CL3-a to CL3-r or CL4-a to
CL4-r. Port names are not case sensitive
This option always must be specified if –pd raw_device
option is not specified.
[hgrp] is specified to display only the LDEVs mapped
to a host group on a port for disk array.
–pd[g] raw_device
Specifies a raw_device name.
Finds the seq# and port name on the disk array and
scans the port of the disk array (which corresponds to
the unit ID) and searches for the unit ID from seq#.