HP XP Continuous Access Software User Manual
Page 132
132
HP StorageWorks Disk Array XP RAID Manager: User’s Guide
–m MU
#
Specifies the mirror descriptor for BC/SnapShot
volumes. CA volumes do not specify a mirror
descriptor.
–i inst
#
Specifies the instance number for RM.
–s
service
Specifies the service name to be used in the newly
created configuration file. If not specified, 52323 will
be used as a default.
–a
Used to add a new volume group within the newly
created configuration file.
–c
drive#
(Windows NT/2000/2003 only)
Specifies the range of
drive numbers to be searched for existing command
devices. If not specified, hd0-99 will be used as the
default.
–c
(OpenVMS only)
Specifies the range of drive numbers
to be searched for existing command devices. If not
specified, DKA0-10000 DGA0-10000 will be used as
the default.
Example
This example demonstrates the usage of the mkconf command and the
resulting configuration file.
HP-UX
# cd /tmp/test
# cat /etc/horcmperm.conf | /HORCM/usr/bin/mkconf.sh -g ORA -i 9 -m 0
starting HORCM inst 9
HORCM inst 9 starts successfully.
HORCM Shutdown inst 9 !!!
A CONFIG file was successfully completed.
starting HORCM inst 9
HORCM inst 9 starts successfully.
DEVICE_FILE Group PairVol PORT TARG LUN M SERIAL LDEV
/dev/rdsk/c23t0d0 ORA ORA_000 CL2-J 0 0 0 61456 192
/dev/rdsk/c23t0d1 ORA ORA_001 CL2-J 0 1 0 61456 193
/dev/rdsk/c23t0d2 ORA ORA_002 CL2-J 0 2 0 61456 194
/dev/rdsk/c23t0d3 ORA ORA_003 CL2-J 0 3 0 61456 195
/dev/rdsk/c23t0d4 ORA ORA_004 CL2-J 0 4 0 61456 256
/dev/rdsk/c23t0d5 ORA ORA_005 CL2-J 0 5 0 61456 257
/dev/rdsk/c23t0d6 ORA ORA_006 CL2-J 0 6 0 61456 258
/dev/rdsk/c23t0d7 - - - - - 0 61456 259