HP XP Continuous Access Software User Manual
Page 328

328
HP StorageWorks Disk Array XP RAID Manager: User’s Guide
Table terms:
XXX
Pair status of P-VOL that was returned by the
pairvolchk –s or pairvolchk –s –c
command.
YYY
Pair status of S-VOL that was returned by the
pairvolchk –s or pairvolchk –s –c
command.
PAIR STATUS
Since the P-VOL controls status, PAIR STATUS is
reported as PVOL_XXX (except when the P-VOLs
status is Unknown).
PVOL-PSUE
PVOL-PSUE-takeover
PVOL-SMPL
PVOL-SMPL-takeover
Nop
Nop-takeover
Swap
swap-takeover
When the horctakeover command execution succeeds, the state transitions
to that of the shown (
→) number.
XP256 microcode 52-47-xx and under
XP512/48 microcode 10-00-xx and under
With older firmware, a horctakeover used to result in a SMPL S-VOL,
which necessitated a full copy at failback time. See “Swap-takeover
function”
SVOL
SVOL-SMPL takeover
SVOL_E
Execute SVOL-SMPL takeover and return
EX_VOLCUR.
SVOL_E*
Execute SVOL-SMPL takeover and return
EX_VOLCUR.