beautypg.com

HP XP Continuous Access Software User Manual

Page 244

background image

244

HP StorageWorks Disk Array XP RAID Manager: User’s Guide

This option is effective without specification of the –g
group

option.

If the volume is contained in two groups, the command
is executed on the first volume encountered. If MU# is
not specified, it defaults to 0.

–d

[g] seq# LDEV# [MU#]

Searches the RM instance configuration file (local
instance) for a volume that matches the specified
sequence # and LDEV. If a volume is found, the
command is executed on the paired logical volume (–d)
or group (–dg).

This option is effective without specifying the –g group
option.

If the volume is contained in two groups, the command
is executed on the first volume encountered only.

seq# LDEV#

can be specified in hexadecimal by

addition of 0x, or decimal.

–f

[xde]

–fx

displays the LDEV/STLBA/ENLBA number in

hexadecimal.

–fd

displays the relationship between the Device_File

and the paired volumes, based on the group (as defined
in the local instance configuration definition file). If the
Device_File column shows “unknown” to either the
local or the remote host (instance), then the volume is
not recognized on the current host, and the command is
rejected in protection mode.

Example

raidvchkdsp -g vg01 -fd -v cflag

Group PairVol Device_File Seq# LDEV# BR-W-E-E MR-W-B BR-W-B SR-W-B-S

vg01 oradb1 c4t0d2 2332 2 D E B R D D D D E E D E D D

vg01 oradb2 c4t0d3 2332 3 D E B R D D D D E E D E D D

This manual is related to the following products: