Examples – HP XP Continuous Access Software User Manual

Page 153

background image

153

Examples

(BC Only)

# pairdisplay –g oradb

Group

Pair Vol(L/R) (Port#,TID,LU-M), Seq#, LDEV#...P/S,

Status, Seq#,

P-LDEV# M

oradb

oradb1(L)

(CL1-A, 1, 1-0)

30053 18 ...P-VOL PAIR

30053

19

-

oradb

oradb1(R)

(CL1-D, 1, 1-0)

30053 19 ...S-VOL PAIR

----

18

-

(CA only)

# pairdisplay –g oradb –fcx

Group

Pair Vol(L/R) (P,T#,L#),

Seq#, LDEV# P/S,

Status, Fence,

%,

P-LDEV# M

oradb

oradb1(L)

(CL1-B, 1,0)

1234

64

P-VOL PAIR

Never,

75

C8

-

oradb

oradb1(R)

(CL1-A, 1,0)

5678

C8

S-VOL PAIR

Never,

--- 64

-

The following shows the output when using –CLI. The format aligns the
column data in each row, making it easier to parse. The delimiters between
columns are either a space or –.

Group PairVol L/R Port# TID LU-M Seq# LDEV# P/S Status Seq# P-LDEV# M

homrcf1 deva0 L CL1-D 3 5 0 30053 271 P-VOL PAIR 30053 263 -

homrcf1 deva1 L CL1-D 3 5 1 30053 271 SMPL - - - -

homrcf1 deva2 L CL1-D 3 5 2 30053 271 SMPL - - - -

The following example uses –fd.

# pairdisplay -g oradb -fd

Group PairVol(L/R) Device_File M ,Seq#,LDEV#.P/S,Status, Seq#,P-LDEV# M

oradb oradev1(L) c0t3d0 0 35013 17..P-VOL COPY, 35013 18 -

oradb oradev1(R) c0t3d1 0 35013 18..S-VOL COPY, 35013 17 -

The following figure shows cascading volumes, using the –m option.

PVOL

266

S/P

VOL

268

SVOL

270

SVOL

272

Oradb(CA)

Oradb1

Oradb2

0

1

0

SMPL

Seq#30052

Seq#30053