beautypg.com

HP XP Continuous Access Software User Manual

Page 194

background image

194

HP StorageWorks Disk Array XP RAID Manager: User’s Guide

Other than 0 to 127 (For the error cause and details, see the execution logs):

236:EX_ENQVOL

237:EX_CMDIOE

235:EX_EVOLCE . . . When the –c argument is specified

242:EX_ENORMT. . . When the –c argument is specified

16:EX_EXTCTG

214:EX_ENQCTG

When a volume group contains volumes in different states, one state will
take precedence and will be reported for the group as shown in the
following table.

Option

COPY

PSUE

PDUB

PFUS

PSUS

PFUL

PAIR

Group

Status

–s

1

x

x

x

x

x

x

COPY*

0

1

x

x

x

x

x

PSUE

0

0

1

x

x

x

x

PDUB

0

0

0

1

x

x

x

PFUS

0

0

0

0

1

x

x

PSUS

0

0

0

0

0

1

x

PFUL

0

0

0

0

0

0

1

PAIR

–ss

1

x

x

x

x

x

x

COPY*

0

1

x

x

x

x

x

PSUE

0

0

1

x

x

x

x

PDUB

0

0

0

x

x

1

x

PFUL

0

0

0

x

x

0

1

PAIR

0

0

0

1

0

0

0

PFUS

0

0

0

0

1

0

0

PSUS

This manual is related to the following products: