HP XP Continuous Access Software User Manual
Page 274
274
HP StorageWorks Disk Array XP RAID Manager: User’s Guide
EX_ENLDEV
A device defined in the configuration
file does not have an assigned LUN,
port, or target ID.
Verify that the configuration file is
correct and that all devices are defined
correctly.
EX_ENOCTG Not enough CT groups. Could not
register because 15 CTs (XP256), 63
CTs (XP512), 127 CTs (XP1024), or
255 CTs (XP12000) are already in use.
Decrease the number of CTs in use, or
use the pairvolchk command to display
the CTs in use; then use paircreate with
–f async
CTGID or -mgrp CTGID to
specifically assign new pairs to existing
CTs.
EX_ENODEV
The designated device name does not
exist in the configuration file.
Verify the device name and add it to the
configuration file of the remote and local
hosts.
EX_ENOENT
The designated device or group name
does not exist in the configuration file.
Verify the device or group name and add
it to the configuration file of the remote
and local hosts.
EX_ENOGRP
The designated device or group name
does not exist in the configuration file,
or the network address for remote
communication does not exist for the
specified group name.
Verify the device or group name and add
it to the configuration file of the remote
and local hosts.
EX_ENOMEM
Insufficient memory.
Increase the virtual memory of the
system, or close any unnecessary
programs.
EX_ENORMT
A timeout error occurred.
Verify that the local and remote servers
are properly communicating, and
increase the timeout value in the
configuration file.
EX_ENOSUP
S-VOL error
Verify the microcode version by using
the raidqry -l command
EX_ENOUNT
The disk array unitID that was
designated as a command argument
does not exist in the configuration file.
Verify the disk array unitID and add it to
the HORCM_CMD section of the local
host configuration file.
(continued)
Command Error Problem
Action