beautypg.com

Hcicatcdecreasepowerrequest, Hcicatcdisconnect, Hcicatcdecreasepowerrequest hcicatcdisconnect – Teledyne LeCroy BTTracer_Trainer - BTTrainer Users Manual User Manual

Page 167

background image

149

CATC BTT

RAINER

2.11

C

HAPTER

User’s Manual

status = Disconnect('00803713BDF0');

Trace("Disconnect result: ", status, "\n");

}

}

HCICatcDecreasePowerRequest

HCICatcDecreasePowerRequest(HCI_Handle)

Return value

Command Status: Will return after the operation has started

Command Complete: will return after the operation has completed.

Comments

This command will send LMP_Decr_Power_Req PDU to the remote
device predefined number of times.

Example

Main()

{

Device = '008037163567';

result = HCICatcIncreasePowerRequest(Device);

Trace("HCICatcIncreasePowerRequest: ", result, "\n");

result = HCICatcDecreasePowerRequest(Device);

Trace("HCICatcDecreasePowerRequest: ", result, "\n");

return result;

}

HCICatcDisconnect

HCICatcDisconnect(HCI_Handle,Mode,Timeout))

Parameter

Meaning

Default Value

Comments

HCI_Handle

Parameter

Meaning

Default Value

Comments

HCI_Handle

Mode

Values:
0-Tester Detach
1-IUT Detach
2-Link Supervision(Slave)
3- Link Supervision(Master)

Timeout

Timeout value (in ms)