A.16.4 catc_acceptconnectionext, Catc_acceptconnectionext – Teledyne LeCroy BTTracer_Trainer - BTTrainer Users Manual User Manual
Page 151

133
CATC BTT
RAINER
2.20
A
PPENDIX
A
User’s Manual
L_CH=01, L_CH=10, L_CH=11 - Defines payload header L_CH value and type of
payload to be sent. Data payload of L_CH=11b is restricted to a pseudo-random value that
does not match any existing LMP PDU.
Duration - Set time in msec.
Time Length - Enter a value in msec.
Error Type - Presents a menu of error types.
Error Mask - Defines error distribution. Insert an error into a payload or in to header. This
option is context sensitive and depends on the type of error selected
Example:
1. error_type = FEC 1/3 header, and error_mask=8000, 1-bit error is inserted into the header
and the error bit will be the first bit in header.
2. error_type = FEC 2/3 payload, and error_mask=0c00, 2-bit error is inserted into the
payload and the error bits will be the 5th and 6th bits in payload.
When running base band tests, make sure the mask starts from left (no leading zeros) since
the FW will apply error mask to every bit depends on how many time the test will run.
PBRS - If checked, will generate random data.
Data Pattern - Define a pattern to be matched.
Tx Jitter - Random jitter range from -9.5 to 9.5. Check '+0.5us' box is 0.5 jitter as needed.
Hops Sequence - presents a menu with three options: 79 Hops Standard, Fixed Frequency,
and Reduced Hop.
Poll Repetion - Presents a text box for entering a time value.
Power Control - Presents a menu with two options: Adaptive power control and Fixed Tx
Output Power.
A.16.4 CATC_AcceptConnectionExt
This command supports TCI functionality that requires BTTrainer to be connected as a
slave device. The command will accept an incoming connection request from the master,
and configure BTTrainer to perform the specified test. This command can be executed
several times outside the connection context to modify testing conditions.
Command Parameters
Examples
Comments
TestScenario
Other Parameters in SetErrors dialog
Return Events
Command Status: Will return after the operation has started.
Command Complete: Will return after the operation has completed.