Rainbow Electronics W90P710CDG User Manual
Page 368
W90P710CD/W90P710CDG
- 368 -
Timer Interrupt Status Register (TISR)
REGISTER
ADDRESS
R/W
DESCRIPTION
RESET VALUE
TISR
0xFFF8_1018 R/W Timer Interrupt Status Register
0x0000_0000
31
30
29
28
27
26
25
24
Reserved
23
22
21
20
19
18
17
16
Reserved
15
14
13
12
11
10
9
8
Reserved
7
6
5
4
3
2
1
0
Reserved TIF1
TIF0
BITS
DESCRIPTIONS
[1]
TIF1
Timer Interrupt Flag 1
This bit indicates the interrupt status of Timer channel 1.
0 = It indicates that the Timer 1 dose not countdown to zero yet.
1 = It indicates that the counter of Timer 1 has decremented to zero.
The interrupt flag is set if it was enable.
NOTE: This bit is read only, but can be cleared by writing 1 to this bit.
[0]
TIF0
Timer Interrupt Flag 0
This bit indicates the interrupt status of Timer channel 0.
0 = It indicates that the Timer 0 dose not countdown to zero yet.
1 = It indicates that the counter of Timer 0 has decremented to zero.
The interrupt flag is set if it was enable.
NOTE: This bit is read only, but can be cleared by writing 1 to this bit.
Watchdog Timer Control Register (WTCR)
REGISTER
ADDRESS
R/W
DESCRIPTION
RESET VALUE
WTCR
0xFFF8_101C R/W
Watchdog Timer Control Register
0x0000_0400