Rainbow Electronics W90P710CDG User Manual
Page 200
![background image](/manuals/280969/200/background.png)
W90P710CD/W90P710CDG
- 200 -
BITS
DESCRIPTIONS
[31:16]
Reserved
[15] RUM_CLKS
Interrupt status for RESUME (for clock is stopped)
0: No Interrupt Generated
1: Interrupt Generated
[14]
RSTENDS
Interrupt status for USB reset end
0: No Interrupt Generated
1: Interrupt Generated
[13] USB_CGS
Interrupt Status for USB Device Configured
0: No Interrupt Generated
1: Interrupt Generated(configured and dis-configured)
[12] USB_BTS
Interrupt Status for USB Bus Transition
0: No Interrupt Generated
1: Interrupt Generated
[11] CVSS
Interrupt Status for Status Phase of Class or Vendor Command
0: No Interrupt Generated
1: Interrupt Generated
[10] CDIS
Interrupt Status for Data-In of Class or Vendor Command
0: No Interrupt Generated
1: Interrupt Generated
[9] CDOS
Interrupt Status for Data-Out of Class or Vendor Command
0: No Interrupt Generated
1: Interrupt Generated
[8] VENS
Interrupt Status for USB Vendor Command
0: No Interrupt Generated
1: Interrupt Generated
[7] CLAS
Interrupt Status for USB Class Command
0: No Interrupt Generated
1: Interrupt Generated