During configuration, the error message "F:10" can appear. This error
indicates a missing Security Device. It occurs because Security Devices are
not implemented on ITG Trunk 2.0. Ignore this message.
See
"ITG-Pentium 24-port trunk card faceplate maintenance display codes"
for a complete list of faceplate codes.
Ethernet status LEDs
Ethernet status LEDs for the voice interface on the daughterboard display
the Ethernet activity as follows:
•
Green is always on if the carrier (link pulse) is received from the TLAN
Ethernet hub.
•
Yellow flashes when there is data activity on the TLAN Ethernet hub.
•
During heavy traffic, yellow can stay continuously lit.
There are no Ethernet status LEDs for the ELAN network interface on the
motherboard.
Reset switch
A reset switch on the faceplate allows an operator to manually reset the
card without having to cycle power to the card. This switch is normally used
following a software upgrade to the card or, alternatively, to clear a fault
condition.
PC Card socket
There are two PC Card sockets. The faceplate socket accepts either a Type
I, a Type II, or a Type III PC Card and is designated ATA device A:. The
internal socket is reserved for the NTWE07AA C7LIU DCH PC Card on
the DCHIP.
Maintenance display
This is a four character, LED-based dot matrix display. It shows the card
boot sequence and is labeled with the card role as follows:
•
LDR = Active Leader
•
BLDR = Backup Leader
•
FLR = Follower
A properly-functioning IP trunk card displays one of the above codes. If an
IP trunk card encounters a problem, a fault code is displayed. For more
information, see
"Media Card 32-port trunk card faceplate maintenance
and
"ITG-Pentium 24-port trunk card faceplate
maintenance display codes" (page 423)