Install and configure IP Trunk 3.01 (and later) node
Prompt
Response
Description
It might be necessary to configure partial IP trunk cards
due to WAN traffic capacity limitations, or Leader and
DCHIP card real-time capacity for very large nodes and
networks.
TYPE
TIE
TN
XX XX
Terminal number
l s c u
Format for Large System, Call Server 1000E, and Media
Gateway 1000E, where l = loop, s = shelf, c = card, u = unit
c u
Format for Small System and Media Gateway 1000B
where c = card and u = unit
DES
16 character descriptive designator for the IP trunk card.
See Note 1
hhhh:hh:hh:hh:h
h
For unit 0. The IP trunk card ELAN network interface
MAC address.
xxx.xxx.xxx.xxx
For units 1 – 23. The IP trunk card ELAN network interface
IP address.
XTRK
Extended Trunk Type: IP trunk card (1-slot or 2-slot
assembly).
MC32
Single slot, 32-port StrongArm (SA) processor Media
Card.
MC24
Double slot, 24-port Pentium processor Media Card.
MAXU
xx
Maximum number of ports on this IP trunk card,
where:
xx = 32 for the Media Card 32-port trunk card
xx = 24 for the ITG-Pentium 24-port trunk card
A warning message is printed if a number larger than 24
is entered for MAXU. Ignore this warning for the Media
Card 32-port trunk card.
CUST
xx
Customer number as defined in LD 15.
RTMB
Route number and Member Number
0-511 1-4000
Range for Large System, Call Server 1000E, and Media
Gateway 1000E
0-127 1-4000
Range for Small System and Media Gateway 1000B.
Nortel Communication Server 1000