beautypg.com

Nortel Networks NN43001-563 User Manual

Page 379

background image

Access the ITG shell through a maintenance port or Telnet

379

configured for the ITG shell. The directory path, which is "/A:", and
file name indicate the software file on the PC Card in the A: drive.

4

Press Enter. Monitor the status of the software upgrade and check
that the upgrade correctly finishes. Observe any error messages
that indicate problems with parameters or syntax.

5

When the new software has downloaded into the flash ROM device,
reboot the IP trunk card to use it. Use the

cardReset

command or

press the reset button on the IP trunk card faceplate.

—End—

Upgrade IP trunk card software through an FTP host

Follow the steps in

Procedure 66 "Upgrading IP trunk card software through

an FTP host" (page 379)

to upgrade the IP trunk card software through

an FTP host.

Procedure 66

Upgrading IP trunk card software through an FTP host

Step

Action

1

Make the latest IP trunk card software, obtained from the Nortel web
page, available to an FTP host. This can be an FTP host on the PC.
As a special case, the FTP host can be the IP trunk card.

Alternatively, use an FTP client running on the PC to copy the IP
trunk card software file to an IP Trunk 3.01 (and later) host on the
network that is available to the IP trunk card.

For example, any IP trunk card on the same IP Trunk 3.01 (and later)
node can serve as the FTP host. The file can be copied onto the C:
drive of the IP trunk card serving as the FTP host.

2

Use the

swDownload

command to copy the software from the PC

Card to the IP trunk card flash ROM device, using the FTP client and
the FTP host on the card. The host name parameter in this command
is the IP address of the FTP host, which can be local or remote to
the IP trunk card. The user name and password are the user name
and password of the FTP host. The directory path and file name are
the directory path and file name on the FTP host. As a special case,
the FTP host can be the IP trunk card and the directory path is "/C:".

3

Press Enter. Monitor the status of the software upgrade and check
that the upgrade correctly finishes. Observe any error messages
that indicate problems with parameters or syntax.

Nortel Communication Server 1000

IP Trunk Fundamentals

NN43001-563

01.01

Standard

Release 5.0

30 May 2007

Copyright © 2007, Nortel Networks

.