Ntmf29ba dchip cable, Procedure 15 assembling the dchip cable – Nortel Networks NN43001-563 User Manual
Page 211
![background image](/manuals/194294/211/background.png)
Cabling for the Media Card 32-port trunk card
211
•
1 stop bit, no parity
•
no flow control
NTMF29BA DCHIP cable
The NTMF29BA DCHIP cable connects to port 0 of the DCHIP PC Card
and the MSDL/SDI DCHIP cable.
Port 1 on the DCHIP PC Card is not used.
The DCHIP PC Card, which connects to NTMF04BA and NTND26AA
Cable, is keyed to allow insertion only in the correct direction. Refer to
Figure 45 "NTMF29BA PC Card DCHIP cable installation" (page 211)
Figure 45
NTMF29BA PC Card DCHIP cable installation
To assemble the DCHIP cable, follow the steps in
.
Procedure 15
Assembling the DCHIP cable
Step
Action
1
Insert the DCHIP bracket through the small slot to the left of the PC
Card opening in the faceplate, as shown in
PC Card DCHIP cable installation" (page 211)
.
2
Fit the screw through the secondary side of the Media Card 32-port
trunk card into the threaded hole in the bracket and tighten.
Nortel Communication Server 1000
IP Trunk Fundamentals
NN43001-563
01.01
Standard
Release 5.0
30 May 2007