Nortel Networks NN43001-563 User Manual
Page 473
Before you begin
473
advanced ISDN features.
Table 2 "Software packages for Meridian
1/CS 1000M IP Trunk 3.01 (and later)" (page 33)
lists required
software packages.
3
Check the Nortel website to find the latest ITG 8-port trunk card
software. Go to
. Follow the links to Customer
Support and Software Distribution or go to
.
The file to download is for the ITG 2.8.xx.mms. "ITG 2" indicates it
is ITG Trunk 2.0 software, "8" indicates it is for the ITG 8-port trunk
card, and "xx" is the software revision level.At the time of release of
IP Trunk 3.01 (and later), the latest version of software was for the
ITG 8-port trunk card was ITG 2.8.26g.
WARNING
It is critical that only the ITG 8-port trunk card software is
installed on the ITG 8-port trunk cards. If the ITG-Pentium
24-port software is installed, the ITG 8-port trunk card
becomes unusable and must be returned to Nortel for
repair.
4
If ITG-Pentium 24-port trunk cards are added to the ITG 8-port
trunk card node as part of the upgrade, verify that the required LAN
networking equipment and cables are installed. For networking
equipment requirements, refer to
"ITG engineering guidelines" (page
. Leader 0 and Leader 1 must be on the same TLAN subnet.
5
If an ITG 8-port trunk card is being upgraded to support DCHIP
functionality, one hardware upgrade kit (NTZC47AA for Large
systems, and NTZC47BA for Small systems) is required. Both kits
contain a DCH PC Card (NTWE07) a pigtail cable (NTCW84EA)
and two versions of the I/O panel breakout cable. The NTZC47AA
contains a D-Channel interface cable (NTND26AA) that extends from
a 15-pin filter in the I/O panel to the MSDL card. The NTZC47BA
contains an external D-Channel cable (NTWE04AD) to connect to
the I/O breakout cable on the SDI/DCH card.
6
Open a Telnet session to the ITG 8-port trunk card. At the ITG>
prompt, enter
itgCardShow
Write down the IP trunk card’s IP address and other card data.
7
If required for an ITG 8-port trunk card upgrade, install an MSDL
card (minimum vintage NT6D80) or SDI/DCH card (minimum vintage
NTAK02BB). Be sure to install the I/O panel breakout cable for the
SDI/DCH card. If cards are in place, make sure each card has an
available port.
Nortel Communication Server 1000
IP Trunk Fundamentals
NN43001-563
01.01
Standard
Release 5.0
30 May 2007
Copyright © 2007, Nortel Networks
.