Nortel Networks NN43001-563 User Manual
Page 392

392
Maintenance
Alarm
Description
Fault Clearing Action
ITG0301
DSP channel not responding. DSP
channel is disabled. Card sends
message to the system to busy the
trunk. This ensures that user’s calls
go through on good DSPs.
These DSP errors are not cleared
automatically. If the occurs frequently,
replace the card.
ITG0302
DSP device failure. Operating on
reduced capacity. DSP failed to
return to normal service.
Hardware fault cleared by automatic trap.
ITG0303
DSP subsystem failure. Initiating card
reboot. DSP fatal error detected.
Hardware fault cleared by automatic trap.
ITG0304
Cannot write to file. I/O error.
Can indicate /C: drive corruption.
ITG0305
Cannot open configuration file. Using
default settings. Can occur after a
reboot.
ITG0306
System messaging error threshold
exceeded. Too many invalid A07 or
X12 messages.
ITG0308
Address translation failure. Call is
released.
ITG0309
Unexpected DSP channel closed.
Channel is unusable.
ITG0310
Cannot open DSP channel.
ITG0311
Unable to get response from
Follower card. Card can be
unplugged.
ITG0312
Unable to push BOOTP tab file to
Backup Leader.
ITG0350
Gatekeeper RAS reject threshold
exceeded.
ITG0351
Cannot open Gatekeeper
configuration file. Using default
settings.
Major Alarms – Immediate intervention required
These alarms indicate an irrecoverable failure of the IP trunk card. Normal operation can only be
restored through manual intervention.
ITG0400
Fatal self-test failure. Card is out of
service. A fatal self-test diagnostic
error was found.
ITG0401
Reboot threshold exceeded.
Manual intervention required.
Nortel Communication Server 1000
IP Trunk Fundamentals
NN43001-563
01.01
Standard
Release 5.0
30 May 2007
Copyright © 2007, Nortel Networks
.