Install and configure IP Trunk 3.01 (and later) node
CAUTION
Equipment Damage
Do not overtighten screws. They can break.
Follow the steps in
Procedure 7 "Installing and cabling the ITG-Pentium
24-port trunk card" (page 192)
on
Procedure 7 "Installing and cabling
the ITG-Pentium 24-port trunk card" (page 192)
to install and cable the
ITG-Pentium 24-port trunk card.
Procedure 7
Installing and cabling the ITG-Pentium 24-port trunk card
Step
Action
1
Identify the IPE card slots selected for the IP trunk card(s). Use the
recorded information from the IP Trunk 3.01 (and later) Installation
Summary Sheet (
Table 38 "IP Trunk 3.01 (and later) Installation
).
2
Remove any existing I/O panel cables associated with any card
previously installed in the selected card slot.
3
Install the NTWE07AA DCHIP PC Card into the internal PC Card slot
on the IP trunk card that has been selected to provide the DCHIP
function. (See
Figure 34 "DCHIP PC Card and NTCW84EA pigtail
on
Figure 34 "DCHIP PC Card and NTCW84EA
.)
4
Connect the NTCW84EA pigtail cable from port 0 of the DCHIP PC
Card to the J14 pin header on the motherboard of the DCHIP card.
See
Figure 34 "DCHIP PC Card and NTCW84EA pigtail cable"
.
The cable routes the D-Channel signals to the backplane and the I/O
panel. The PC Card connector is keyed to allow insertion only in the
correct direction. The J-14 pin header connector is not keyed. Be
careful to align the connector with the pin header.