Dchip cable routing, Meridian 1 option 11c cabinet/cs 1000m cabinet – Nortel Networks NN43001-563 User Manual
Page 213
![background image](/manuals/194294/213/background.png)
Cabling for the Media Card 32-port trunk card
213
NTMF04BA MSDL extension cable
The NTMF04BA cable connects the NTND26AA MSDL cable and the
NTMF29BA DCHIP cable, when the Common Equipment shelf and the
IPE shelf are in separate columns and not connected by internal cabling
channels. A 15-way mounting block (A03511331) is shipped with the
NTMF04BA cable. The mounting block, when mounted on the Common
Equipment shelf I/O panel, allows the connection of the NTND26AA and the
NTMF04BA cables. The NTMF04BA cable is then routed externally to the
IPE I/O panel to connect with the NTMF29BA DCHIP. See
system DCHIP cabling setup: inter-column" (page 213)
Figure 47
Large system DCHIP cabling setup: inter-column
When the Universal Equipment Modules (UEM) are stacked vertically, or
the UEM columns are bolted together, they are cabled in an inter-column
configuration. See
Figure 47 "Large system DCHIP cabling setup:
. This applies when the UEM system columns
are physically separated and the DCHIP must exit the systems through
the I/O panel.
DCHIP Cable Routing
Meridian 1 Option 11C Cabinet/CS 1000M Cabinet
The following cables are specific to Meridian 1 Option 11C Cabinet/CS
1000M Cabinets. Cable connection details are shown in
11C DCHIP system cabling" (page 214)
.
Nortel Communication Server 1000
IP Trunk Fundamentals
NN43001-563
01.01
Standard
Release 5.0
30 May 2007