When the ITG-Pentium 24-port trunk card starts up, it performs multiple
self-tests. The faceplate display shows the test results.
If self-tests T:00-T:09 fail, the self-test program stops and the faceplate
displays an "F:xx" message to indicate which test failed. For example, if the
timer test T:05 fails, "F:05" is displayed. If more than one test fails, the
message displayed indicates the first failure.
If self-tests T:10-T:17 fail, the display contains the failure message for three
seconds and the ITG-Pentium 24-port trunk card goes on to the next test. If
more than one test fails, the message displayed indicates the last failure.
Table 70
ITG-Pentium 24-port trunk card faceplate maintenance display message
summary
Normal
Code
Fault
Code
Description
T:00
F:00
Initialization
T:01
F:01
Testing Internal RAM
T:02
F:02
Testing ALU
T:03
F:03
Testing address modes
T:04
F:04
Testing Boot ROM
T:05
F:05
Testing timers
T:06
F:06
Testing watchdog
T:07
F:07
Testing external RAM
T:08
F:08
Testing Host DPRAM
T:09
F:09
Testing DS30 DPRAM
T:10
F:10
Testing for presence of security device. The
ITG-Pentium 24-port trunk card has no security device.
For the ITG-Pentium 24-port trunk card, a momentary
display of F:10 is normal.
T:11
F:11
Testing flash memory
T:12
F:12
Programming PCI FPGA
T:13
F:13
Programming DS30 FPGA
T:14
F:14
Programming CEMUX FPGA
T:15
F:15
Programming DSP FPGA
T:16
F:16
Testing CEMUX interface
T:17
F;17
Testing EEPROM