424

Maintenance

When the ITG-Pentium 24-port trunk card starts up, it performs multiple
self-tests. The faceplate display shows the test results.

If self-tests T:00-T:09 fail, the self-test program stops and the faceplate
displays an "F:xx" message to indicate which test failed. For example, if the
timer test T:05 fails, "F:05" is displayed. If more than one test fails, the
message displayed indicates the first failure.

If self-tests T:10-T:17 fail, the display contains the failure message for three
seconds and the ITG-Pentium 24-port trunk card goes on to the next test. If
more than one test fails, the message displayed indicates the last failure.

Table 70
ITG-Pentium 24-port trunk card faceplate maintenance display message
summary

Normal
Code

Fault
Code

Description

T:00

F:00

Initialization

T:01

F:01

Testing Internal RAM

T:02

F:02

Testing ALU

T:03

F:03

Testing address modes

T:04

F:04

Testing Boot ROM

T:05

F:05

Testing timers

T:06

F:06

Testing watchdog

T:07

F:07

Testing external RAM

T:08

F:08

Testing Host DPRAM

T:09

F:09

Testing DS30 DPRAM

T:10

F:10

Testing for presence of security device. The
ITG-Pentium 24-port trunk card has no security device.

For the ITG-Pentium 24-port trunk card, a momentary
display of F:10 is normal.

T:11

F:11

Testing flash memory

T:12

F:12

Programming PCI FPGA

T:13

F:13

Programming DS30 FPGA

T:14

F:14

Programming CEMUX FPGA

T:15

F:15

Programming DSP FPGA

T:16

F:16

Testing CEMUX interface

T:17

F;17

Testing EEPROM

Nortel Communication Server 1000

IP Trunk Fundamentals

NN43001-563

01.01

Standard

Release 5.0

30 May 2007

Copyright © 2007, Nortel Networks

.