beautypg.com

FUJITSU MB91F109 FR30 User Manual

Page 289

background image

265

10.11 Setting Examples of Baud Rates and U-TIMER Reload Values

10.11 Setting Examples of Baud Rates and U-TIMER Reload

Values

Tables 10.11-1 and 10.11-2 are sample settings for baud rates and U-TIMER reload
values.
The frequencies in the tables indicate peripheral machine clock frequencies. UCC1
indicates the value to set in the UCC1 bit of the U-TIMER control register (UTIMC).
A hyphen "-" in the tables indicate that the corresponding value cannot be used
because the error exceeds plus or minus 1%.

Sample Settings for Baud Rates and U-TIMER Reload Values

Asynchronous (start-stop) mode

CLK synchronous mode

*1: The error exceeds plus or minus 1%.

Table 10.11-1 Baud Rates and U-TIMER Reload Values in Asynchronous (Start-Stop) Mode

Baud rate

µµµµ

s

25 MHz

20 MHz

12.5 MHz

10 MHz

1200

833.33

650 (UCC1=0)

520 (UCC1=0)

324 (UCC1=1)

259 (UCC1=1)

2400

416.67

324 (UCC1=1)

259 (UCC1=1)

162 (UCC1=0)

129 (UCC1=0)

4800

208.33

162 (UCC1=0)

129 (UCC1=0)

80 (UCC1=1)

64 (UCC1=0)

9600

104.17

80 (UCC1=1)

64 (UCC1=0)

39 (UCC1=1)

31 (UCC1=1)

19200

52.08

39 (UCC1=1)

31 (UCC1=1)

19 (UCC1=1)

-

38400

26.04

19 (UCC1=1)

-

12 (UCC1=1)

-

57600

17.36

12 (UCC1=1)

-

-

-

10400

96.15

74 (UCC1=0)

59 (UCC1=0)

36 (UCC1=1)

29 (UCC1=0)

31250

32.00

24 (UCC1=0)

19 (UCC1=0)

11 (UCC1=1)

9 (UCC1=0)

62500

16.00

11 (UCC1=1)

9 (UCC1=0)

-

4 (UCC1=0)

Table 10.11-2 Baud Rates and U-TIMER Reload Values in CLK Synchronous Mode

Baud rate

µµµµ

s

25 MHz

20 MHz

12.5 MHz

10 MHz

250 K

4.00

49 (UCC1=0)

39 (UCC1=0)

24 (UCC1=0)

19 (UCC1=0)

500 K

2.00

24 (UCC1=0)

19 (UCC1=0)

11 (UCC1=1)

9 (UCC1=0)

1 M

1.00

11 (UCC1=1)

9 (UCC1=0)

5 (UCC1=0)*

1

4 (UCC1=0)