265
10.11 Setting Examples of Baud Rates and U-TIMER Reload Values
10.11 Setting Examples of Baud Rates and U-TIMER Reload
Values
Tables 10.11-1 and 10.11-2 are sample settings for baud rates and U-TIMER reload
values.
The frequencies in the tables indicate peripheral machine clock frequencies. UCC1
indicates the value to set in the UCC1 bit of the U-TIMER control register (UTIMC).
A hyphen "-" in the tables indicate that the corresponding value cannot be used
because the error exceeds plus or minus 1%.
■
Sample Settings for Baud Rates and U-TIMER Reload Values
❍
Asynchronous (start-stop) mode
❍
CLK synchronous mode
*1: The error exceeds plus or minus 1%.
Table 10.11-1 Baud Rates and U-TIMER Reload Values in Asynchronous (Start-Stop) Mode
Baud rate
µµµµ
s
25 MHz
20 MHz
12.5 MHz
10 MHz
1200
833.33
650 (UCC1=0)
520 (UCC1=0)
324 (UCC1=1)
259 (UCC1=1)
2400
416.67
324 (UCC1=1)
259 (UCC1=1)
162 (UCC1=0)
129 (UCC1=0)
4800
208.33
162 (UCC1=0)
129 (UCC1=0)
80 (UCC1=1)
64 (UCC1=0)
9600
104.17
80 (UCC1=1)
64 (UCC1=0)
39 (UCC1=1)
31 (UCC1=1)
19200
52.08
39 (UCC1=1)
31 (UCC1=1)
19 (UCC1=1)
-
38400
26.04
19 (UCC1=1)
-
12 (UCC1=1)
-
57600
17.36
12 (UCC1=1)
-
-
-
10400
96.15
74 (UCC1=0)
59 (UCC1=0)
36 (UCC1=1)
29 (UCC1=0)
31250
32.00
24 (UCC1=0)
19 (UCC1=0)
11 (UCC1=1)
9 (UCC1=0)
62500
16.00
11 (UCC1=1)
9 (UCC1=0)
-
4 (UCC1=0)
Table 10.11-2 Baud Rates and U-TIMER Reload Values in CLK Synchronous Mode
Baud rate
µµµµ
s
25 MHz
20 MHz
12.5 MHz
10 MHz
250 K
4.00
49 (UCC1=0)
39 (UCC1=0)
24 (UCC1=0)
19 (UCC1=0)
500 K
2.00
24 (UCC1=0)
19 (UCC1=0)
11 (UCC1=1)
9 (UCC1=0)
1 M
1.00
11 (UCC1=1)
9 (UCC1=0)
5 (UCC1=0)*
1