4 Start-Up Programming

96

YASKAWA TOEPYAIL1E01A YASKAWA AC Drive L1000E Quick Start Guide

S4-07: UPS Power

Sets the capacity of the UPS.

S4-08: UPS Operation Speed Limit Selection

Determines how a speed limit should be applied to the Rescue Operation speed (S4-15) when operating from a UPS. The
drive calculates the appropriate speed limit based on the UPS capacity set in S4-07. This speed limit helps prevent voltage
saturation and motor stall during Rescue Operation.

Setting 0: Disabled
Setting 1: Enabled until Light Load Direction Search is complete
Setting 2: Enabled until stop

S4-12: DC Bus Voltage during Rescue Operation

Sets the DC bus voltage during Rescue Operation.

S4-13: Rescue Operation Power Supply Deterioration Detection Level

Determines at which level of backup power supply deterioration a PF5 fault is triggered. The following conditions will
trigger PF5:

• During Rescue Operation, DC bus voltage < [S4-12

× (S4-13 - 10%)]

• 100 ms after Rescue Operation has been triggered, the DC bus voltage does not rise above S4-12

× S4-13 before the

motor starts

S4-15: Speed Reference Selection at Rescue Operation

Selects the speed reference used for Rescue Operation.

Setting 0: The setting of parameter d1-25 is used as speed reference for Rescue Operation
Setting 1: The speed selected by digital inputs is used as speed reference

No.

Parameter Name

Setting Range

Default

S4-07

UPS Power

0.0 to 100.0 kVA

0.0 kVA

No.

Parameter Name

Setting Range

Default

S4-08

UPS Operation Speed Limit Selection

0 to 2

2

No.

Parameter Name

Setting Range

Default

S4-12

DC Bus Voltage during Rescue Operation

0 to 1150 V

0 V

No.

Parameter Name

Setting Range

Default

S4-13

Rescue Operation Power Supply Deterioration Detection Level

10 to 100%

80%

No.

Parameter Name

Setting Range

Default

S4-15

Speed Reference Selection for Rescue Operation

0, 1

0