Start-up flowcharts, Switching between local and remote, 4 start-up programming – Yaskawa L1000E AC Drive CIMR-LEA User Manual
Page 61: For details on the types of auto-tuning, Using the lo/re key on the digital operator
4 Start-Up Programming
YASKAWA TOEPYAIL1E01A YASKAWA AC Drive L1000E Quick Start Guide
61
St
ar
t-
Up
Pr
og
ra
m
m
in
g
4
■
Switching Between LOCAL and REMOTE
LOCAL mode is when the drive is set to accept the Up/Down command from the digital operator keypad. REMOTE
mode is when the drive is set to accept the Up/Down command from an external device (via the input terminals or serial
communications, etc.).
Switch the operation between LOCAL and REMOTE using the LO/RE key on the digital operator or via a digital input.
This key is disabled with default settings, but can be enabled by setting parameter o2-01 to 1.
Note: 1. After selecting LOCAL, the LO/RE light will remain lit.
2. The drive will not allow the user to switch between LOCAL and REMOTE during run.
Using the LO/RE Key on the Digital Operator
◆ Start-Up Flowcharts
This section covers basic setup for the drive, including Auto-Tuning procedures and corresponding flowcharts. Follow the
flowchart that matches the motor used in your application. Refer to
Types of Auto-Tuning on page 68
for details on the
types of Auto-Tuning.
Step
Display/Result
1.
Turn on the power to the drive. The initial display appears.
2.
Press
. The LO/RE light will light up. The drive is now in LOCAL.
To set the drive for REMOTE operation, press
again.
Flowchart
Purpose
Page
A
Installation, wiring, and basic steps required to setup the motor and elevator for operation
B
Auto-Tuning for induction motors
C
Auto-Tuning for PM motors
D
Encoder Offset Auto-Tuning
- MODE -
U1-01= 0.00%
U1-02= 0.00%
U1-03= 0.00A
DRV
Speed Ref(A1/A2)
Rdy
RSEQ
RREF
FWD
FWD/REV
YEA_
com-
LO
RE
F2
F1
ESC
RUN
STOP
ENTER
RESET
ALM
DIGITAL OPERATOR JVOP-180
- MODE -
U1-01= 0.00%
U1-02= 0.00%
U1-03= 0.00A
DRV
Speed Ref (OPR)
Rdy
LSEQ
LREF
FWD
YEA
_ c o
mm