B Parameter Table

190

YASKAWA TOEPYAIL1E01A YASKAWA AC Drive L1000E Quick Start Guide

L3: Stall Prevention

L4: Speed Detection

No.

(Addr.)

Name

Description

Setting

L3-01

(48FH)

<16> The setting value is dependent on the setting for the carrier frequency reduction (L8-38).

Stall Prevention Selection
during Acceleration

0: Disabled.
1: General purpose. Acceleration is paused as long as the current is above the
L3-02 setting.
2: Intelligent. Accelerate in the shortest possible time without exceeding the L3-
02 level.

Default: 1
Min: 0
Max: 2

L3-02

(490H)

Stall Prevention Level during
Acceleration

Used when L3-01 = 1 or 2. 100% is equal to the drive rated current.

Default:

<16>

Min: 0%
Max: 150%

<16>

L3-05

(493H)

Stall Prevention Selection
during Run

0: Disabled. Drive runs at a set frequency. A heavy load may cause speed loss.
1: Decel time 1. Uses the deceleration ramp set to C1-02 while Stall Prevention
is performed.
2: Decel time 2. Uses the deceleration ramp set to C1-04 while Stall Prevention
is performed.

Default: 1
Min: 0
Max: 2

L3-06

(494H)

Stall Prevention Level during
Run

Enabled when L3-05 is set to 1 or 2. 100% is equal to the drive rated current.

Default:

<16>

Min: 30%
Max: 150%

<16>

No.

(Addr.)

Name

Description

Setting

L4-01

(499H)

Speed Agreement Detection
Level

L4-01 sets the speed detection level for digital output functions H2-

= 3, 4,

5.
L4-02 sets the hysteresis or allowable margin for speed detection.

Default: 0.0%
Min: 0.0%
Max: 100.0%

L4-02

(49AH)

Speed Agreement Detection
Width

Default: 4.0%
Min: 0.0%
Max: 40.0%

L4-03

(49BH)

Speed Agreement Detection
Level (+/-)

L4-03 sets the speed detection level for digital output functions H2-

= 13,

14, 15, 16.
L4-04 sets the hysteresis or allowable margin for speed detection.

Default: 0.0%
Min: –100.0%
Max: 100.0%

L4-04

(49CH)

Speed Agreement Detection
Width (+/-)

Default: 4.0%
Min: 0.0%
Max: 40.0%

L4-05

(49DH)

Speed Reference Loss
Detection Selection

0: Stop. Drive stops when the speed reference is lost.
1: Run. Drive runs at a reduced speed when the speed reference is lost.

Default: 0
Min: 0
Max: 1

L4-06

(4C2H)

Speed Reference at
Reference Loss

Sets the percentage of the speed reference that the drive should run with when
the speed reference is lost.

Default: 80%
Min: 0.0%
Max: 100.0%

L4-07

(470H)

Speed Agree Detection Selection

0: No detection during baseblock
1: Detection always enabled

Default: 0
Min: 0
Max: 1

L4-13

(4F6H)

Door Zone Level

Sets the door zone speed level. The "door zone" multi-function digital output is
closed when the speed falls below this level.

Default: 0.0%
Min: 0.0%
Max: 100.0%

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_