Operator programming errors, Ope codes, causes, and possible solutions – Yaskawa L1000E AC Drive CIMR-LEA User Manual
Page 137
5 Troubleshooting
YASKAWA TOEPYAIL1E01A YASKAWA AC Drive L1000E Quick Start Guide
137
Tr
ou
blesh
oot
ing
5
◆ Operator Programming Errors
■
oPE Codes, Causes, and Possible Solutions
An Operator Programming Error (oPE) occurs when a contradictory parameter is set or an individual parameter is set to
an inappropriate value.
The drive will not operate until the parameter or parameters causing the problem are set correctly. An oPE, however, does
not trigger an alarm or fault output. If an oPE occurs, investigate the cause and refer to
for the appropriate
action. When an oPE appears on the operator display, press the ENTER button to view U1-18 and see which parameter is
causing the oPE.
Table 34 oPE Codes, Causes, and Possible Solutions
Digital Operator Display
Error Name
oPE01
Drive Capacity Setting Fault
Drive capacity and the value set to o2-04 do not match.
oPE02
Parameter Range Setting Error
Use U1-18 to find parameters set outside the range.
oPE03
Multi-function Digital Input Selection Error
A contradictory setting is assigned to multi-function contact inputs H1-03 to H1-08.
oPE04
Terminal Board Mismatch Error
oPE05
Reference Source Selection Error
oPE06
Control Mode Selection Error
Correct the setting for the control method.
oPE07
Multi-function Analog Input Selection Error
A contradictory setting is assigned to multi-function analog inputs H3-02 and H3-10.
oPE08
Parameter Selection Error
A function has been set that cannot be used in the motor control method selected.
oPE10
V/f Pattern Setting Error
The following setting errors have occurred where:
E1-04 is greater than or equal to E1-06, E1-06 is greater than or equal to E1-07, E1-07 is greater than or
equal to E1-09, or E1-09 is greater than or equal to E1-11.
oPE16
Energy Savings Constants Error
oPE18
Parameter Setting Error, Online Tuning Parameter Setting Error
• The input from load cell with load condition 1 (S3-29) is set to the same value as load condition 2 (S3-
30).
• DWELL 2 related parameters are not set correctly.
• Parameters that control Online Tuning are not set correctly.
oPE20
PG-F3 Setting Error
The encoder signal frequency is too high.
oPE21
Elevator Parameter Setting Fault
Elevator parameters are not set correctly.