S3-03

(699H)

Position Lock Gain at Stop

Sets the Position Lock gain at stop. Position Lock at stop keeps the car in
position until the brake has been applied entirely.

Default: 5
Min: 0
Max: 100

S3-04

(69AH)

Position Lock Bandwidth

Determines the bandwidth around the stop position in which a digital output
programmed for "Within Position Lock Bandwidth" (H2-

= 33) is closed.

Default: 10
Min: 0
Max: 16383

S3-10

(69BH)

Starting Torque
Compensation Increase Time Sets a time constant for the torque reference to reach 300%. Enabled by setting

an analog input terminal for torque compensation (H3-

= 14).

Default: 500 ms
Min: 0 ms
Max: 5000 ms

S3-12

(69DH)

Starting Torque
Compensation Bias in Down
Direction

Adds a bias to torque compensation value from the load cell when moving in
down direction.

Default: 0
Min: -40.0%
Max: 40.0%

S3-14

(69FH)

Torque Compensation Fade
Out Speed

Sets the speed level for torque compensation to fade out during the time
determined by S3-15. Sets as a percentage of the maximum output frequency
(E1-04). A setting of 0.0% essentially disables this function.

Default: 0.0%
Min: 0.0%
Max: 100.0%

S3-15

(6A0H)

Torque Compensation Fade
Out Time

Sets the time for torque compensation to fade out once motor speed reaches the
level set in S3-14.

Default: 1000 ms
Min: 0 ms
Max: 5000 ms

S3-16

(6A1H)

Torque Limit Reduction Time

Determines the reduction rate used bring the internal torque reference value
down to zero after Position Lock at Stop has finished.
Rate =

Default: 100 ms
Min: 0 ms
Max: 10000 ms

S3-20

(6A2H)

Dwell 2 Speed Reference

Sets the speed reference for the Dwell 2 function.
Note: A setting of 0.00 essentially disables the Dwell 2 function.

Default: 0.00%
Min: 0.00%
Max: 100.00%

S3-21

(6A5H)

Dwell 2 End Speed

The Dwell 2 function will end when the drive reaches this speed.
Note: A setting of 0.00 will disable the acceleration rate switch that occurs at the
end of Dwell 2.

Default: 0.00%
Min: 0.00%
Max: 100.00%

S3-25

(6A3H)

DC Injection Gain in
Regenerative Operation

Sets the gain level applied to the DC injection current at stop (S1-03) for when
the load is 100% regenerative. The current applied during DC Injection at stop is
determined as S1-03

× S3-25.

Default: 100%
Min: 0%
Max: 400%

S3-26

(6A4H)

DC Injection Gain in
Motoring Operation

Sets the gain level applied to the DC injection current at stop (S1-03) for when
the load is 100% motoring. The current applied during DC Injection at stop is
determined as S1-03

× S3-26.

Default: 20%
Min: 0%
Max: 400%

S3-27

(6BDH)

Torque Compensation Value
with Load Condition 1

Used for starting torque compensation utilizing a load cell signal. Sets the torque
compensation value for load condition 1.

Default: –50%
Min: –100%
Max: 100%

S3-28

(6BEH)

Torque Compensation Value
with Load Condition 2

Used for starting torque compensation utilizing a load cell signal. Sets the torque
compensation value for load condition 2.

Default: 50%
Min: –100%
Max: 100%

S3-29

(6BFH)

Analog Input from Load Cell
with Load Condition 1

Used for starting torque compensation utilizing a load cell signal. Sets the analog
signal level from the load cell for load condition 1.

Default: 0.0%
Min: –100%
Max: 100%

No.

(Addr.)

Name

Description

Setting

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

Torque 300%

S3-16

common

_

All Modes

common

_

All Modes

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV