beautypg.com

Currents, B parameter table – Yaskawa L1000E AC Drive CIMR-LE†A User Manual

Page 170

background image

B Parameter Table

170

YASKAWA TOEPYAIL1E01A YASKAWA AC Drive L1000E Quick Start Guide

C6: Carrier Frequency

No.(Addr.)

Name

Description

Setting

C6-03

(225H)

<4> Default setting value varies by the drive model (o2-04).

Carrier Frequency

Sets the carrier frequency.

Default:

<4>

Min: 1.0 kHz
Max: 15.0 kHz

C6-06

(228H)

PWM Method

Selects PWM modulation method.
0: 2-phase/3-phase conversion
1: 2-phase modulation
2: 3-phase modulation

Default: 0
Min: 0
Max: 2

C6-09

(22BH)

Carrier Frequency during
Rotational Auto-Tuning

0: Carrier Frequency = 5 kHz
1: Setting value for C6-03

Default: 0
Min: 0
Max: 1

C6-21

(245H)

Inspection Operation Carrier
Frequency

Sets the carrier frequency during Inspection Run.
0: Setting value for C6-03
1: Carrier Frequency = 2 kHz

Default: 1
Min: 0
Max: 1

C6-23

(25EH)

Carrier Frequency during
Initial Motor Pole Search

Sets the carrier frequency when estimating the initial polarity.
0: Carrier Frequency = 2 kHz
1: Setting value for C6-03

Default: 0
Min: 0
Max: 1

C6-31

(77AH)

Carrier Frequency during
Rescue Operation

Sets the carrier frequency during Rescue Operation.
0: C6-03 setting
1: 2 kHz

Default: 0
Min: 0
Max: 1

All Modes

common

_

All Modes

common

_

common

_

CLV

CLV/PM

V/f

OLV

All Modes

common

_

common

_

CLV

CLV/PM

V/f

OLV

All Modes

common

_