U4-07

(7D7H)

IGBT Maintenance

Displays IGBT usage time as a percentage of the expected performance life.
The IGBTs should be replaced when this monitor reaches 90%. Parameter o4-
09 can be used to reset this monitor.

No signal output
available

1%

U4-08

(68H)

Heatsink Temperature

Displays the heatsink temperature.

10 V: 100

°C

1

°C

U4-09

(5EH)

LED Check

Lights all segments of the LED to verify that the display is working properly.

No signal output
available

U4-10
(5CH)

kWh, Lower 4 Digits

Monitors the drive output power. The value is shown as a 9 digit number
displayed across two monitor parameters, U4-10 and U4-11.
Example:
12345678.9 kWh is displayed as:
U4-10: 678.9 kWh
U4-11: 12345 MWh

No signal output
available

1 kWh

U4-11

(5DH)

kWh, Upper 5 Digits

No signal output
available

1 MWh

U4-13

(7CFH)

Peak Hold Current

Displays the highest current value that occurred during a ride.

No signal output
available

0.01 A

<40>

U4-14

(7D0H)

Peak Hold Output
Frequency

Displays the output frequency when the current value shown in U4-13
occurred.

No signal output
available

0.01 Hz

U4-16

(7D8H)

Motor Overload Estimate
(oL1)

Shows the value of the motor overload detection accumulator. 100% is equal
to the oL1 detection level.

10 V: 100%

0.1%

U4-17

(7D9H)

Drive Overload
Calculations (OL2)

Displays the level of the drive overload detection (oL2). A value of 100% is
equal to the oL2 detection level.

10 V = 100%

0.1%

U4-18

(7DAH)

Speed Reference
Selection Results

Displays the source for the speed reference as XY-nn.
X: indicates which reference is used:
1 = Reference 1 (b1-01)
Y-nn: indicates the reference source
0-01 = Digital operator
1-01 = Analog (terminal A1)
1-02 = Analog (terminal A2)
2-02 to 8 = Digital Inputs (d1-02 to 8)
3-01 = MEMOBUS/Modbus communications
4-01 = Communication option card

No signal output
available

U4-19

(7DBH)

Speed Reference from
MEMOBUS/Modbus
Comm.

Displays the speed reference provided by MEMOBUS/Modbus (decimal).

No signal output
available

0.01%

<31>

U4-20

(7DCH)

Speed Reference From
Option Card

Displays the speed reference input by an option card (decimal).

No signal output
available

0.01%

<31>

No.

(Addr.)

Name

Description

Analog Output

Level

Unit

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_