S: Elevator Parameters

This section describes various functions and faults needed to operate an elevator application: braking sequence, slip
compensation for elevators, start/stop optimization, Rescue Operation, and elevator-related faults.

S1: Brake Sequence

o4-13

(528H)

Number of Travels Counter
Reset

0: Keep the number of travels counter value. The counter is not reset when the
drive is initialized (A1-03).
1: Resets the number 0 travels counter. The monitor U4-24/25 will show 0. Once
o4-13 is set to 1 and the ENTER key is pressed, the counter value is erased and
the display returns to 0.

Default: 0
Min: 0
Max: 1

o4-15

(537H)

<1>

Maintenance Alarm Snooze
Period

After a maintenance alarm output has been triggered, o4-15 determines the level
that will trigger the next alarm for the same component. The same alarm will be
triggered by the detection level that triggered the original alarm plus the level set
in o4-15.

Default: 2%
Min: 0%
Max: 20%

o4-16

(176H)

<1>

Maintenance Monitoring
Selection

Selects the Maintenance Monitor using bits 0 to 3.
0: LT1 (cooling fan)
1: LT2 (DC bus capacitors)
2: LT3 (soft-charge bypass relay)
3: LT4 (IGBTs have passed 90% of the their life expectancy)

Default: 1000
Min: 0000
Max: 1111

<1> Parameter setting value is not reset to the default value during drive initialization (A1-03).

No.

(Addr.)

Name

Description

Setting

S1-01

(680H)

Zero Speed Level at Stop

Determines the speed to begin applying DC Injection (or Position Lock) when
the drive is ramping to stop (b1-03 = 0). Set as a percentage of the maximum
output frequency (E1-04).

Default:

<1>

Min: 0.000%
Max: 9.999%

S1-02

(681H)

DC Injection Current at Start Determines the amount of current to use for DC Injection at start. Set as a

percentage of the drive rated current.

Default: 50%
Min: 0%
Max: 100%

S1-03

(682H)

DC Injection Current at Stop Determines the amount of current to use for DC Injection at stop. Set as a

percentage of the drive rated current.

Default: 50%
Min: 0%
Max: 100%

S1-04

(683H)

DC Injection/Position Lock
Time at Start

Determines how long the drive should perform DC Injection at start. In CLV and
CLV/PM, S1-04 determines how long Position Lock should be performed. A
setting of 0.00 disables S1-04.

Default: 0.40s
Min: 0.00 s
Max: 10.00 s

S1-05

(684H)

DC Injection/Position Lock
Time at Stop

Determines how long the drive should perform DC Injection at stop. In CLV and
CLV/PM, S1-05 determines how long Position Lock should be performed. A
setting of 0.00 disables S1-05.

Default: 0.60s
Min: 0.00 s
Max: 10.00 s

S1-06

(685H)

Brake Release Delay Time

Determines the delay time between the start of DC injection/Position Lock and
setting the brake control command (H2-

=50) in order to release the brake at

the beginning of the ride.

Default: 0.20s
Min: 0.00 s
Max: 10.00 s

No.

(Addr.)

Name

Description

Setting

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

All Modes

common

_

All Modes

common

_

All Modes

common

_