B Parameter Table
YASKAWA TOEPYAIL1E01A YASKAWA AC Drive L1000E Quick Start Guide
209
Pa
ra
me
te
r T
abl
e
B
U1-10
(49H)
Input Terminal Status
Displays the input terminal status.
No signal output
available
–
U1-11
(4AH)
Output Terminal Status
Displays the output terminal status.
No signal output
available
–
U1-12
(4BH)
Drive Status
Displays the drive operation status.
No signal output
available
–
U1-13
(4EH)
Terminal A1 Input
Voltage
Displays the voltage input to terminal A1.
10 V: 100%
(-10 to +10 V)
0.1%
U1-14
(4FH)
Terminal A2 Input
Voltage
Displays the voltage input to terminal A2.
10 V: 100%
(-10 to +10 V)
0.1%
No.
(Addr.)
Name
Description
Analog Output
Level
Unit
All Modes
common
_
U1 - 10= 00000000
Digital input 1
(terminal S1 enabled)
Digital input 2
(terminal S2 enabled)
Digital input 3
(terminal S3 enabled)
Digital input 4
(terminal S4 enabled)
Digital input 5
(terminal S5 enabled)
Digital input 6
(terminal S6 enabled)
Digital input 7
(terminal S7 enabled)
Digital input 8
(terminal S8 enabled)
1
1
1
1
1
1
1
1
Y E A _
c o m -
All Modes
common
_
U1 - 11= 00000000
Multi-Function
Digital Output
(terminal M1-M2)
Digital Output
(terminal M3-M4)
Digital Output
(terminal M5-M6)
Multi-Function
Multi-Function
Digital Output
(terminal P1-C1)
Multi-Function
Digital Output
(terminal P2-C2)
Multi-Function
Not Used
Fault Relay
(terminal MA-MC closed
MA-MC open)
1
1
1
1
1
1
YEA_c
o m -
All Modes
common
_
U1 - 12= 00000000
During run
During zero-speed
During down direction
During fault reset
signal input
During speed agree
Drive ready
During alarm
detection
During fault detection
1
1
1
1
1
1
1
1
YEAc
o m -
All Modes
common
_
All Modes
common
_