beautypg.com

Y e a _ c o m, 4 start-up programming – Yaskawa L1000E AC Drive CIMR-LE†A User Manual

Page 111

background image

4 Start-Up Programming

YASKAWA TOEPYAIL1E01A YASKAWA AC Drive L1000E Quick Start Guide

111

St

ar

t-

Up

Pr

og

ra

m

m

in

g

4

Refer to the following table to install the inrush current suppression circuit for battery.

Table 31 Installation of the Inrush Current Suppression Circuit for Battery

Voltage

<1> Select the appropriate relay referring to the following calculation even if the battery voltage or main power current is applied.

Drive Model

CIMR-LE

Resistor

Relay

200 V

2A0269

1.0

Ω, 80 W

<1>

2A0354

1.0

Ω, 80 W

2A0432

1.0

Ω, 80 W

400 V

4A0188

1.0

Ω, 120 W

4A0225

1.0

Ω, 220 W

4A0260

1.0

Ω, 220 W

Load current of battery (A) =

Motor rated power (kW)

× Operation frequency when running battery (Hz) × 2 × 1000

Battery voltage (Vdc)

× 0.6 (Motor efficiency) × Motor rated frequency (Hz)