T: Motor Tuning
Enter data into the following parameters to tune the motor and drive for optimal performance.
S5-13
(6D6H)
Direct Landing Minimum
Speed Level
Sets the speed level for the start of Direct Landing.
Direct Landing is essentially disabled if the starting speed for Direct Landing is
less than the maximum output speed multiplied by this parameter (E1-04
× S5-
13).
Default: 20%
Min: 0%
Max: 100%
<36> When the length units are set for inches (o1-12 = 1), the setting range becomes 0.00 to 650.00 inches.
<37> When the length units are set for inches (o1-12 = 1), the setting range becomes 0.00 to 393.00 inches.
No.
(Addr.)
Name
Description
Setting
S6-01
(6B3H)
<1> Default setting value is determined by the digital operator display unit selection (o1-03). The default is normally 1.5 m/s
2
, but when o1-03 = 6,
the default becomes 5.0 ft/s
2
(Setting Range: 0.0 to 50.0 ft/s
2
).
Motor Contactor Response
Error (SE1) Detection/Reset
Selection
0: Detect during stop, SE1 must be manually reset
1: Detect during stop, SE1 can be automatically reset
2: No SE1 detection
Default: 0
Min: 0
Max: 2
S6-02
(6B4H)
Starting Current Error (SE2)
Detection Delay Time
Sets a delay time for detecting SE2.
Default: 200 ms
Min: 0.00 ms
Max: [S1-04]-[S1-
06]
S6-03
(6B5H)
SE2 Detect Current Level
Sets the level of current applied to the motor when the Brake Control command
is activated, as a percentage of the Motor No-load Current (E2-03).
Default: 25%
Min: 0%
Max: 100%
S6-04
(6B6H)
Output Current Error (SE3)
Detection Delay Time
Sets a delay time for detecting SE3.
Default: 200 ms
Min: 0 ms
Max: 5000 ms
S6-05
(6B7H)
Brake Response Error (SE4)
Detection Time
Sets a delay time for detecting SE4.
Default: 500 ms
Min: 0 ms
Max: 10000 ms
S6-10
(6B8H)
Overacceleration Detection
Level
If the elevator car accelerates at an abnormal rate, the drive triggers an overspeed
fault (dv6) and has the motor coast to stop. Parameter S6-10 determines the
acceleration rate that triggers a fault.
Default:
Min: 0.0 m/s
2
Max: 20.0 m/s
2
S6-11
(6B9H)
Overacceleration Detection
Time
Sets a primary delay for detecting overacceleration.
Default: 50 ms
Min: 0 ms
Max: 5000 ms
S6-12
(6BAH)
Overacceleration Detection
Selection
0: Always enabled
1: During run only
Default: 0
Min: 0
Max: 1
S6-15
(6BBH)
Speed Reference Loss
Detection
Enabled or disables detection for speed reference missing (FrL).
0: Disabled
1: Enabled
Default: 1
Min: 0
Max: 1
S6-16
(6BCH)
Restart after Baseblock
Selection
0: No restart after Baseblock/Safe Torque-Off
1: Restart after Baseblock/Safe Torque-Off
Default: 0
Min: 0
Max: 1
No.
(Addr.)
Name
Description
Setting
CLV
CLV/PM
V/f
OLV
common
_
common
_
All Modes
common
_
CLV
CLV/PM
V/f
OLV
common
_
CLV
CLV/PM
V/f
OLV
common
_
CLV
CLV/PM
V/f
OLV
All Modes
common
_
common
_
CLV
CLV/PM
V/f
OLV
common
_
CLV
CLV/PM
V/f
OLV
common
_
CLV
CLV/PM
V/f
OLV
All Modes
common
_
All Modes
common
_