S5-10: stopping method selection, S5-11: deceleration distance, S5-12: stop distance – Yaskawa L1000E AC Drive CIMR-LE†A User Manual

Page 102: 4 start-up programming, Selects the stopping method

background image

4 Start-Up Programming

102

YASKAWA TOEPYAIL1E01A YASKAWA AC Drive L1000E Quick Start Guide

Figure 57 Operation Sequence Example for Leveling Distance Control

S5-10: Stopping Method Selection

Selects the stopping method.

Setting 0: Disable
Setting 1: Direct Landing
Setting 2: Leveling Distance Control

S5-11: Deceleration Distance

Sets the deceleration distance when Stop Distance Control is enabled.

Refer to Direct Landing on page 100

for details.

S5-12: Stop Distance

Sets the stopping distance when Stop Distance Control is enabled. Refer to

Direct Landing on page 100

and

Leveling

Distance Control on page 101

for details.

<1> Area S is the stopping distance (S5-12) from the point at which leveling operation is complete to when the car arrives at the designated

floor.

No.

Parameter Name

Setting Range

Default

S5-10

Stopping Method Selection

0 to 2

0

No.

Parameter Name

Setting Range

Default

S5-11

<1> The setting range becomes 0.00 to 650.00 inches when the length units are set for inches (o1-12 = 1).

Deceleration Distance

0 to 32767 mm

<1>

0 mm

No.

Parameter Name

Setting Range

Default

S5-12

<1> The setting range becomes 0.00 to 393.00 inches when the length units are set for inches (o1-12 = 1).

Stop Distance

0 to 10000 mm

<1>

0 mm

Operation
Speed

Time

ON

OFF

OFF

OFF

OFF

ON

ON

ON

Run Command Delay Time (S1-10)

Brake Release Delay Time

Brake Close
Delay Time

ON

Zero Speed

at Start

(S1-06)

Zero Speed

at Stop

(S1-07)

Output Contactor Open
Delay Time (S1-11)

Run Command
(Forward [Up] / Reverse [Down])

H2-

= 53 (Not Zero Speed

)

H2-

= 51

(Output Contactor Control

)

H1-

= 56

(Motor Contactor Feedback

)

H2-

= 50 (Brake Control

)

S

<1>