Drive Overheat Pre-alarm (oH)

Closed: Heatsink temperature exceeds the parameter L8-02 value.

2F

Maintenance Period

Closed: Cooling fan, electrolytic capacitors, IGBTs, or the soft charge bypass relay may require
maintenance.

30

During Torque Limit

Closed: When the torque limit has been reached.

33

Within Position Lock
Bandwidth

Closed: Position deviation is within the Position Lock Bandwidth.

37

During Frequency Output

Open: No frequency output from drive when stopped with baseblock, stopped with DC injection
braking during initial excitation, or stopped with short circuit braking.
Closed: Drive is outputting a frequency.

47

Input Phase Loss

Closed: Input phase loss has occurred
Open: Normal operation (no phase loss detected)

4E

Braking Transistor Fault (rr)

Closed: The built-in dynamic braking transistor failed.
Note: This function is not available in models 2A0181 to 2A0432 and 4A0094 to 4A0260.

50

Brake Control

Close: Release brake
Open: Apply brake

51

Output Contactor Control

Closed: Close output contactor

52

Door Zone Reached

Closed: Indicates that the door zone has been reached.

53

Not Zero Speed

Closed: Speed is greater than the zero speed level set to S1-01
Open: Operating at zero speed level

54

Light Load Direction

Closed: Light load direction is up
Open: Light load direction is down

55

Light Load Direction Detection
Status

Closed: Ready for Light Load Direction Search
Open: Light Load Detection in progress

58

Safe Disable Status

Closed: Safe Disable terminals H1-HC and H2-HC are open, drive is in a baseblock state
Open: Safe Disable terminals H1-HC and H2-HC are closed (normal operation)

5C

Motor Current Monitor

Open: Output current is greater than the value of L8-99
Closed: Output current is less than or equal to the value of L8-99

60

Internal Cooling Fan Alarm

Closed: Internal cooling fan alarm

61

Motor Pole Search Status

Closed: Motor pole search successful

H2 Multi-Function Digital Output Settings

H2-

Setting

Function

Description

All Modes

common

_

All Modes

common

_

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

common

_

CLV

CLV/PM

V/f

OLV