Yaskawa L1000E AC Drive CIMR-LEA User Manual
Page 43
3 Electrical Installation
YASKAWA TOEPYAIL1E01A YASKAWA AC Drive L1000E Quick Start Guide
43
El
ec
tr
ical
I
n
st
al
la
ti
o
n
3
Input Terminals
lists the input terminals on the drive. Text in parenthesis indicates the default setting for each multi-function
input.
Table 11 Control Circuit Input Terminals
Type
<1> Setting jumper S3 for an external power supply makes the wire jumper between terminals H1, H2, and HC ineffective. Remove the wire jumper
and connect an external power supply that can supply terminals H1, H2, and HC continuously.
No.
Terminal Name (Function)
Function (Signal Level) Default Setting
Page
Digital Inputs
S1
Up Command (Closed: Up, Open: Stop)
Photocoupler
24 Vdc, 8 mA
Use the wire link between terminals SC and SN or between SC
and SP to select sinking or sourcing, and to select the power
supply.
S2
Down Command (Closed: Down, Open: Stop)
S3
Multi-function input 1 (External Fault)
S4
Multi-function input 2 (Fault Reset)
S5
Multi-function input 3 (Multi-Step Speed
Reference 1)
S6
Multi-function input 4 (Multi-Step Speed
Reference 2)
S7
Multi-function input 5 (Multi-Step Speed
Reference 3)
S8
Multi-function input 6 (Not used)
Digital Input
Power Supply
SC
Multi-function input common
24 Vdc, 150 mA (only when DI-A3 is not used)
Use the wire jumper between terminals SC and SN or between SC
and SP to select sinking or sourcing, and to select the power
supply.
SN
0 V
SP
+24 Vdc
Safe Disable
Inputs
H1
Safe Disable input 1
24 Vdc, 8 mA
One or both open: Drive output disabled
Both closed: Normal operation
Internal impedance: 3.3 k
Ω
Off time of at least 1 ms
Set the S3 jumper to select sinking or sourcing, and to select the
power supply.
H2
Safe Disable input 2
HC
Safe Disable function common
Common for the Safe Disable function
Analog Inputs
+V
Power supply for analog inputs
10.5 Vdc (max allowable current 20 mA)
-V
Power supply for analog inputs
-10.5 Vdc (max allowable current 20 mA)
–
A1
Multi-function analog input 1 (Speed
reference bias)
-10 to 10 Vdc, 0 to 10 Vdc (input impedance: 20 k
Ω)
–
A2
Multi-function analog input 2 (Not used)
-10 to 10 Vdc, 0 to 10 Vdc (input impedance: 20 k
Ω)
–
AC
Analog input common
0 V
–
E (G) Ground for shielded lines and option cards
–
–